CLEAN-FLO...Experts in water quality since 1970.


540 East Union Street, Suite I
West Chester, PA 19382
Phone: 610-431-1934 / 1-800-328-6656
Fax: 610-431-1959

info@CLEAN-FLO.com

CLEAN-FLO
CLEAN-FLO
This large reservoir had a serious blue-green algae problem producing bad taste and odor in the drinking water. Taste and odor is gone after inversion and oxygenation of the reservoir by CLEAN-FLO. Lake top half is treated with CLEAN-FLO and bottom half is not treated with CLEAN-FLO.  This small lake demonstrates the effectiveness of CLEAN-FLO products and services in the remediation and management of water.  In this example diffusers and inversion / oxygenation have been employed at a great savings and with total effectiveness. This river was restored from Class 3-4 where Class 4 is “unusable for any purpose” to Class 1-2 where Class 1 is “usable for any purpose.” This hog manure lagoon demonstrates the effectiveness of CLEAN-FLO’s unique aeration in treating wastewater treatment lagoons.  Odor could not be detected when standing on the edge of the lagoon. This lake had two feet of organic muck at the shoreline before CLEAN-FLO treatment. This is a pond using the CLEAN-FLO pond aeration system. Inversion and oxygenation of a bay of the ocean.  This bay of the ocean was highly polluted by industrial and residential waste before CLEAN-FLO treatment.  Inverting and oxygenating bays of the ocean and rivers flowing into the bays can prevent red tide from destroying important fisheries.  Improve water quality, remove odors, improve fish growth, and health and prevent fish kills. This a pond that does not use the CLEAN-FLO pond aeration system.
CLEAN-FLO
CLEAN-FLO

Our System - Continuous Laminar Flow Inversion


The most important part of CLEAN-FLO's unique process is called "Continuous Laminar Flow Inversion and Oxygenation." This process enables the other parts of the process to perform their functions. CLEAN-FLO International invented and perfected this energy efficient process. Unlike ordinary diffused air systems, surface aeration, paddlewheels, hypolimnetic aerators, or propeller-aspirator aerators, CLEAN-FLO oxygenates an entire body of water from top to bottom. CLEAN-FLO oxygenates and rids the entire bottom of gases including ammonia and carbon dioxide which aquatic weeds and algae need for food.

The CLEAN-FLO Continuous Laminar Flow Inversion and Oxygenation process was engineered and developed to duplicate natural spring and fall turnover of a water body. In tropical countries, natural inversion occurs at random with typhoons, cyclones and torrential rains. Natural inversion oxygenates the bottom water and rids the water of toxic gases that accumulate in stagnant water.

The CLEAN-FLO process increases natural twice-a-year inversion of lakes to several times a day or several times a week or month. The amount of inversion depends on CLEAN-FLO’s engineering design to counteract incoming pollutants and pollutants in that particular body of water. We have over thirty-five years of experience restoring lakes, ponds, reservoirs, rivers and wastewater built into our computers to tell us how many inversions are necessary for each body of water. It takes many factors into account, such as incoming water quality and flow rate, retention time of the water body, sediment, weeds, algae, fish-kills, and much more.

The Continuous Laminar Flow Inversion and Oxygenation process carries oxygenated, toxic gas-free surface water down to the bottom of the water body. At the bottom, oxygenated water binds phosphorus and nitrogen to the sediments and kills anaerobic, often pathogenic (disease producing), bacteria that produce acids and toxic gases. The CLEAN-FLO process usually reduces phosphorus and nitrogen in the water body three to twenty times as much as point-source watershed treatment can accomplish.
Continuous Laminar Flow Inversion and Oxygenation enables beneficial microorganisms to feed on bottom organic sediment. It enables aquatic insects to feed on the microorganisms, and fish to inhabit the bottom waters and feed on the insects

Click here to read more about our Pond Aerator System.

Improve lake fishing and improve water chemistry using natural lake processes.  When is the best time to start?

Free Cost Estimate For Your Pond Aeration Treatment

Free Cost Estimate For Your Lake Aeration Project

Free Cost Estimate For Your Reservoir Restoration Project


Free Cost Estimate For Your River Restoration Project

Free Cost Estimate For Your Wastewater Aeration
 

 

Utilizing our proprietary ceramic diffusers, CLEAN-FLO moves the most water possible from the bottom to the surface without creating turbulence.

 

CLEAN-FLO Aerator-type System moves 480,000 gallons per HP-hour in six feet of water to 16,000,000 gallons per hour in 200 feet of water. This picture shows 3,500,000 gallons per hour being raised from 60 feet depth using 1 HP

 

Inverting and aerating a new golf course in Korea with fairway seeded and mulched. Note the CLEAN-FLO cabinet on the shoreline at the right.

 
       
 

 

 

 
             
CLEAN-FLO
CLEAN-FLO

| | |